Instruction manual

21
Essex Electronics, Inc. | 805.684.7601 | 800.KEY-LESS | fax 805.684.0232 | keyless.com
4. Finally 7 0 bits are sent as lead out.
Notes:
! # is the Enter key and * is the Clear key. If # is pressed with no data
key first, there is no output from the keypad.
! If over 12 data keys are pressed before enter, there is no output from the
keypad.
!!
!!
! ABA Track II Connector Wiring
CONFIGURATION
PINS- “CONFIG”
VOLTAGE SELECT
(Do NOT apply voltage)
12-24V (default)- Jumper on
one pin only
5V- Jumper on both pins
YELLOW- RED LED
Control (Do NOT apply
voltage)
PINK- NOT USED
(Do NOT apply voltage)
BLUE- CCTV
BROWN- GREEN LED Control
(Do NOT apply voltage)
TAN- Earth Ground
BLACK- Ground
ORANGE- Invert Data Output
(Do NOT apply voltage)
VIOLET- NOT USED
RED- Input Voltage
WHITE- Data
GREEN- Clock
NOTE: The 2x6 connector is rotated 180 degrees