If the wrong baud rate is selected, pressing the * key before
entering the parity option will clear the entry. The Keypad will
generate an error tone if you enter an invalid number. You
should hear 2 audible beeps and the RED LED will continue
blinking fast while the GREEN LED will blink slow.
2. Parity Option (second digit)
Next, enter the desired second digit on the Keypad to select
the parity option:
0 = None (8 Data Bits)
1 = Odd (7 Data Bits + Odd Parity Bit)
2 = Even (7 Data Bits + Even Parity Bit)
Note: All Parity formats have a single Start and Stop Bit.
If the wrong parity is selected, pressing the * key before
entering the mode option will clear the entry. The Keypad will
generate an error tone if you enter an invalid number. You
should hear 2 audible beeps and the RED LED will continue
blinking fast while the GREEN LED will be solid.
3. Mode (third digit)
To select the desired mode option, enter the desired third digit
on the Keypad:
0 = NORMAL (Single character output with each keystroke)
*Sends ASCII* - #Sends ASCII#
1 = ALTCHAR (Single character output with each keystroke)
*Sends ASCII <ESC> - # Sends ASCII <CR>
2 = BUFFER
BUFFER mode accepts up to 10 characters. If more than 10 charac-
ters are entered, you will hear an error beep and the buffer will be
cleared. Pressing # sends buffered characters + ASCII <CR> at end.
Pressing * clears the buffer and outputs 2 beeps. Clear buffer timeout
set to 10 seconds.