Instruction manual
Essex Electronics, Inc. | 805.684.7601 | 800.KEY-LESS | fax 805.684.0232 | keyless.com
2
Tamper Alarm: 25 Incorrect Key Presses
Access Code Protection: Non-Volatile Memory
Keypad Operating Environment: -40°C to +70°C (-40°F to +160°F),
100% Relative Humidity
Keypad Dimesions –
5-Pad Non-Illuminated: KP-5S, KP-SSL a 6 ⅝” x 2 ¼” x ½”
12-Pad 3x4: KP-34S, KP-34K, KP-34B a
5 ⅛” x 3 ⅜” x 7/16”
Thinline 2x6: KP-26TS, KP-26TI a 7 ⅛” x 1 ¾” x ¾”
Control Module Operating
Environment: -40° C to + 49° C (- 40° C to + 120° F)
Control Module Dimensions: 7½” x 5½” x 2½”
System Specications, cont’d.
Input Requirements
The KE-265 accepts 12 to 24 volts AC/DC. System current draw
(maximum):
Standby: 10mA at 12 volts, 25mA at 24 volts
During Operation: .25 amps max (with illuminated Keypad)
IMPORTANT: The maximum current draw allowed is 1 amp. Check
the specications of your locking device. Make sure that the locking
device and the KE-265 (.25 amps) combined draw less than 1
amp. For locking devices that draw more current, a separate power
supply is required. (Appendix B – page 31.)
Note: If connecting DC, make the connections to “DC IN/OUT”
instead of “12-24V AC/DC IN” (see Circuit Board Layout on page
30). Make sure the polarity is correct.