Instruction manual

Essex Electronics, Inc. | 805.684.7601 | 800.KEY-LESS | fax 805.684.0232 | keyless.com
20
door will remain open after a valid User Code 3, User Code 4 or
User Code 5 has been entered into the system.
Note: For controlling a garage door or electric gate, you will need
to set the door open time to 1 second.
2. Locate the Control Module, remove the cover and locate the
“PROGRAM” switch on the circuit board.
3. Press the PROGRAM switch once *. (The Keypad will beep
rapidly 4 times)
4. At the Keypad, enter 1-1-1-5 to open the memory (you will hear
three rapid beeps) and enter a combination of “1’s” (for every one
second increment) and “5’s” (for every ve second increment)
that equal your desired Door Open Time. Each valid key press (a
“1” or a “5”) will generate a double beep. (Do not let more than
ve seconds elapse between entries or the system will reset!!!)
Example: “1-1-1-5 1-1-5”
a
7 seconds
5. After entering your Door Open Time, wait ve seconds for the 3
reset beeps.
Notes: * Once the PROGRAM switch has been pressed, you have
2 minutes to begin programming. You will hear a double beep with
each valid key press. Once you begin entering the combination
of 1’s and 5’s do not let more than ve seconds elapse between
entries or the system will reset!!! Maximum Door Open Time is 120
seconds.