Instruction manual

17
Essex Electronics, Inc. | 805.684.7601 | 800.KEY-LESS | fax 805.684.0232 | keyless.com
The Master Code can be congured to activate either Relay #1 or
Relay #2 depending on how the system hardware is set up (see
Setting Relay Options on page 11). However, the Master Code
cannot be congured to Latch either relay.
Programming the Master Code
To Program/Change the Master Code:
1. Select a 3 to 8 digit code that will be used for the Master Code.
___ ___ ___ ___ ___ ___ ___ ___
2. Locate the Control Module, remove the cover and locate the
“PROGRAM” switch on the circuit board.
3. Press the PROGRAM switch once *. (The Keypad will beep
rapidly 4 times)
4. At the Keypad, enter 1-1-1-9 to open the memory (you will hear
three rapid beeps) and immediately enter your new Master code.
(Do not let more than ve seconds elapse between entries or the
system will reset!!!)
5. After entering your new code, wait ve seconds for the 3 reset
beeps.
* Once the PROGRAM switch has been pressed, you have 2
minutes to begin programming.
Overview of User Codes
There are a total of 5 User codes (also called Secondary Codes)
that can be programmed into the KE-265. User Codes can vary in
length from 3 to 8 digits. Each User Code is programmed into one.
of 5 User Locations. These Locations are as follows: