Instruction manual
13
Essex Electronics, Inc. | 805.684.7601 | 800.KEY-LESS | fax 805.684.0232 | keyless.com
Example:
1. Placing a jumper across the 2nd and 3rd pins of the “MASTER
UNLOCK” option allows the master code to activate (unlock) Relay
#1.
2. Placing a jumper across the 1st and 2nd pins of the “1,2 UNLOCK”
option allows User Code 1 and User Code 2 to activate Relay #2.
3. Leaving a jumper off the “3,4,5 UNLOCK” option prevents User
Code 3, User Code 4 and User Code 5 from activating either relay.
Latching Authorization
Placing jumpers across the 4th and
5th set of pins (1,2 LATCH or 3,4,5
LATCH) determines which relay (if
any) each User Group is authorized
to manually latch.
How to Latch
When a valid code is entered on
the keypad followed by “7”, the Latch Authorization relay for that
particular User Group will energize and remain energized until a valid
code followed by “7” is entered again.
Example:
1. Placing a jumper across the 1st and 2nd pins of the “1, 2 LATCH”
option allows User 1 and User 2 to Latch Relay #2.
2. Leaving a jumper off the “3,4,5 LATCH” option prevents User 3,
User 4 and User 5 from latching either relay.
Note: Because the Master Code is primarily used to program User
codes, the Master Code does not have Latching Authorization.
Latching Authorization