Instruction manual

Essex Electronics, Inc. | 805.684.7601 | 800.KEY-LESS | fax 805.684.0232 | keyless.com
12
option to be congured. Placing jumpers across the 1st & 2nd pins,
the 2nd & 3rd pins or no pins at all determines how each option is
congured.
To set an Option for Relay #1 a Place jumper across 2nd & 3rd pins.
To set an Option for Relay #2
a Place jumper across 1st & 2nd pins.
To set an Option for No Relay
a Don’t place jumper across 1st & 2nd
or 2nd & 3rd pins.
The Factory Default Settings are shown here:
1. All User Unlock Authorization
is congured for Relay #1.
(Master Code and Users 1,2
and Users 3,4,5).
2. No Code is set for Latching
Authorization of either relay.
3. Neither CCTV nor DOORBELL
is active.
User Unlock Authorization
Placing jumpers across the rst 3
sets of pins (MASTER UNLOCK,
1,2 UNLOCK or 3,4,5 UNLOCK)
determines which relay (if any)
each User Group is authorized to
activate.
When a valid code is entered, the
door will remain unlocked for the
programmed Door Open Time. (See Programming Door Open Time.)
Factory Default Settings
User Unlock Authorization