Instruction manual

27
Essex Electronics, Inc. | 805.684.7601 | 800.KEY-LESS | fax 805.684.0232 | keyless.com
Programming the Keypad with a
Hyper-terminal
1. Set up the Hyper-terminal with the following options:
! 9600 Baud (This is required for the program to work.)
! 8 Data Bits
! No Parity
! 1 Stop Bit
! No Flow Control
! Send line ends with line feeds
! Echo-typed chars locally
! Backspace key sends CTRL+H, SPACE, CTRL+H
2. Connect the ERM Module to the serial port.
3. To Log In, the Keypad must NOT be in the following modes:
Setup, Programming, or Door Input Active.
4. Once logged in, the Keypad will not function until the user
exits the program.
Notes:
! If there is no activity for 60 seconds, the unit will time out and
return to Normal Operation.
! While in Program mode, both LED’s blink fast.
! If 4 invalid Master Codes are entered, the unit will go into
Tamper mode.
! If you have set the Hyper-terminal to send CTRL+H, SPACE,
CTRL+H for backspace, the backspace key will work correctly.
! All commands are case insensitive.