Instruction manual

Essex Electronics, Inc. | 805.684.7601 | 800.KEY-LESS | fax 805.684.0232 | keyless.com
18
2) Enter the desired On Time (1-99 seconds), followed by #
Example: 4 # 1 # 1 5 #
(Sets CCTV/Light Option for 15 seconds)
! Auxiliary Device #1
1) Enter 2 #
2) Enter the momentary output time (1-99 seconds), followed by
# ; -or- Enter 0 to set the auxiliary device for Manual
Operation (ON/OFF), followed by #
Example: 4 # 2 # 0 #
(Sets Auxiliary Device with Manual Operation)
! Second Door
1) Enter 3 #
2) Enter the desired Door Open Time (1-99 seconds), followed
by #
3) Select the desired latching method:
Off- 0 #
Manual- 9 9 #
Timed- Enter the desired time interval in hours (1-98),
followed by #
Example: 4 # 3 # 5 # 9 9 #
(Sets Second Door with 5 second Door Open Time and
Manual Latching)
! Doorbell
1) Enter 4 #
c. Return to Step 3 or enter * * to exit programming.
Keypad Status After Step Completion
Step Beep Red LED Green LED
a Double Slow Flash Slow Flash
1) Double Slow Flash Fast Flash
2) Triple Slow Flash Solid