Instruction manual

17
Essex Electronics, Inc. | 805.684.7601 | 800.KEY-LESS | fax 805.684.0232 | keyless.com
! Setting the Main Door Open Time (Default: 5 Seconds)
a. Enter 2 #
b. Enter the desired Door Open Time (1-99 seconds), followed by #
Example: 2 # 1 5 # (15 sec. Door Open Time)
c. Return to Setp 3 or enter * * to exit programming.
Keypad Status After Step Completion
Step Beep Red LED Green LED
a Double Slow Flash Slow Flash
b Triple Slow Flash Solid
! Setting Latching Option (Default: Off)
a. Enter 3 #
b. Select the desired latching option:
Off- 0 #
Manual- 9 9 #
Timed- Enter the desired time interval in hours (1-98), followed
by #.
Example: 3 # 8 # (Sets timed latching for 8 hrs)
c. Return to Step 3 or enter * * to exit programming.
Keypad Status After Step Completion
Step Beep Red LED Green LED
a Double Slow Flash Slow Flash
b Triple Slow Flash Solid
! Configuring Output A (Default: Aux #1)
a. Enter 4 #
b. Select one of the following:
! CCTV / External Light
1) Enter 1 #