Instruction manual
19
Essex Electronics, Inc. | 805.684.7601 | 800.KEY-LESS | fax 805.684.0232 | keyless.com
! Modify a User by User ID
a. Enter 2 #
b. Enter the User ID (1 to 500) for the User to be modified, followed
by #
c. To change this User’s Code, enter the New User Code followed
by #
d. To keep this User’s Code, enter #. Then, enter the desired User
Authroization, followed by #. (Repeat for additional authorizations
or skip to Step e for no authorizations.)
Code User Authorization
1 Latching Authorization
2 Program or Delete Users Authorization
3 Output A Authorization (see notes)
4 2nd Door (see notes)
5 Output B Authorization (see notes)
6 3rd Door (see notes)
7 24-hour Access (see notes)
e. Enter # to complete programming for this User.
f. To modify an additional User, return to Step b.
g. If no more Users are to be modified, enter
∗∗
∗∗
∗
∗∗
∗∗
∗ and return to
Step 3, or if you have completed all User Programming, enter
∗∗
∗∗
∗
∗∗
∗∗
∗
a second time to complete programming sequence and
reset system to normal operation.
! Modify a User by User Code
a. Enter 3 #
b. Enter the User Code for the User you wish to modify, followed
by #
c. To change this User’s Code, enter the New User Code followed
by #