Internal Alarm
1) Enter 5 #
2) Enter the desired Door Ajar Time (1-99 seconds), follwed
by #
Example: 5 # 5 # 1 0 #
(Sets Internal Door with 10 second Door Ajar Time)
! Master Code Door Unlock Option (Default: Allow)
a. Enter 6 #
b. Enter 0 # to prevent the master code from unlocking the door.
c. Enter 1 # to allow the master code to unlock the door.
d. Return to Step 3 or enter * * to exit programming.
! Time Clock Input (Default: Prevent)
a. Enter 7 #
b. Enter 0 # to prevent lockout
c. Enter 1 # to lockout all users that do not have 24 hour option
enabled.
d. Return to Step 3 or enter * * to exit programming.
! Baud Rate (if using Keypad with Encoded Relay Module)
a. Enter 8 #
b. Enter 0 # to set Baud Rate to 2400
c. Enter 1 # to set Baud Rate to 9600 (default)
4. Enter * * to complete the sequence and reset the system to normal
operation.
Note:
If using a printer or Hyper-terminal with ERM3, 0 # will print Setup
Configuration