Instruction manual
Essex Electronics, Inc. | 805.684.7601 | 800.KEY-LESS | fax 805.684.0232 | keyless.com
10
!!
!!
! Self-Contained Keyless Entry® System
Configuration
Input Requirements
The All-In-One 12-Pad accepts 5VDC or 12 - 24VDC. An optional
battery charging module and rechargeable gel cells are available
when using the ERM-3 module to keep the system operational for
up to 50 hours during a power interruption. System current draw
(max) is as follows:
! Standby: 25mA
! During Operation: 50mA
Output Capabilities
Main Output
The main output is a transistor output intended to drive a relay
(see page 11) that will activate either a Fail-Safe or a Fail Secure
(Non Fail-Safe) electronic locking device or other equipment. It
may also be configured, with an external relay, as a dry contact
relay output to control a gate operator or garage door opener. The
main output is programmable from 01 to 99 seconds with optional
timed or manual latching.
Output A
A transistor output intended to drive a relay that can be pro-
grammed for one of the following:
1. CCTV or Light Controller - First key press triggers a Timed
Output (1 to 99 seconds).
2. Auxiliary Output - Manual Control or Timed Output (1 to 99
seconds).
3. Second Door - Users can be assigned to open a 2nd door.
4. Doorbell - Press # at the Keypad to trigger a 1 second output
for a doorbell (not included).