Instruction manual
Essex Electronics, Inc. | 805.684.7601 | 800.KEY-LESS | fax 805.684.0232 | keyless.com
6
c. To change the illumination on the K1-26 only, enter the
code as follows:
Code Standby Mode Normal Operation
210 # Off (factory default) Off (factory default)
211 # Off Dim
212 # Off Bright
213 # Dim Dim
214 # Dim Bright
You should hear 3 beeps indicating successful configuration
(the RED LED will continue to flash and the GREEN LED will
be solid). If you hear a long error beep, re-enter the configura-
tion number followed by #.
5. Remove power.
6. Remove configuration jumper.
7. Re-apply power.
IMPORTANT: Once the configuration is selected, you must re-
move power, remove the configuration jumper and then re-apply
power in order to complete the configuration procedure. Note: If
the configuration jumper is not removed, the LED's will flash and
the Keypad will beep continuously.
Keypad Reset
In certain cases you may want to erase all user codes and restore
system defaults. To perform this procedure: