Control Pack Codes
VS and GS SERIES Control Pack Codes cont.
DR
Problem: Possible inadequate water, poor flow, or air bubbles in detected in the heater. Spa is
shut down for 15 minutes.
S
olution: Check water level in spa. Refill if necessary. If water level is okay, make sure the pumps
have been primed. Press any button to reset, or this message will automatically reset within 15
minutes. If problem persists, contact customer service or service organization. On a fresh fill
your pump may be air locked. Refer to page 16 for removing an air lock.
DY
Problem: Inadequate water detected in heater. (Displays on third occurrence of “dr” message)
Spa is shut down.
Solution: Follow action required for “dr” message. Spa will not automatically reset. Press any
button to reset. On a fresh fill your pump may be air locked. Refer to page 15 for removing an air
lock.
If you have an error code that will not clear, try the following:
VS and GS Pack Reset Instructions
Tools: Phillips head screwdriver
Needle nose pliers (optional)
First, turn the power off to the spa by using the breaker disconnect. Then, remove the cover to the pack
(electrical control unit inside spa). Locate the board diagram on the inside of the cover, and find J43 Persist-
ent Memory. This is located approximately ¾” above and ½” to the right the red dipswitch bank. It is a small
black piece of plastic located between two yellow pieces connected to the board. The jumper on J43 should
be hanging on one (1) pin and in a vertical position. Using needle nose pliers (or fingers) gently grab the black
jumper and remove from the board. Next, put the jumper back on the pin it came off of in the horizontal po-
sition using it to connect the adjacent pin. Proceed to turn the power back on to the spa. Once you see “PR”
on the top display, wait one (1) minute and turn the breaker back off. Now reverse the process. Take the
black jumper off of both pins and reposition vertically on just one pin (this is done just as a place-saver so
the jumper does not become lost). Replace the cover to the pack, and power the spa back on.
Mode
Standard Mode is programmed to maintain the
desired temperature. Note that the last measured
spa temperature displayed is current only when the
pump has been running for at least 2 minutes. “ST”
will be displayed momentarily when you switch into
Standard Mode. This is the best mode to use during
COLD weather.
Economy Mode heats the spa to the set temper-
ature only during filter cycles or if the temperature
falls to 20 degrees below set temperature. “EC” will
display solid when temperature is not current, and
will alternate with temperature when temperature
is current. This is the best mode to use during
WARM weather.
Sleep Mode also heats the spa to the set temper-
ature only during filtration cycles. “SL” will display
solid when temperature is not current, and will al-
ternate with temperature when temperature is cur-
rent, but only within 20 degrees of your set
temperature.