User Guide Part 8

Administration of the We.R™ System
We.R
™
System User Guide
227
In case the system was not disarmed within the 30 seconds delay period – an alarm
will be triggered and a burglary alarm flow will start (notifications, emails etc.)
A premises exit delay of 30 seconds will be triggered only once the system was armed
via a Tag Reader.
This delay allows the User to arm the system and leave the premises without triggering
an alarm on the way out.
The Tag Reader and Siren (if installed) will sound short beeps to notify the User of this
delay.
Common use of the Entry/Exit feature – usually enabled for a Magnetic Sensor (MGL) installed
on the main entrance door, or for a Motion Detector (PIR) or Camera (IPD) which installed in
the entrance.
Note: Also please refer to paragraph 4.5.4.2 below regarding more
complex installations combining multiple sensors.
4.5.4.2. Devices Allowing Walk-Through
This feature is provided for cases where a Camera (or Motion Detector) device is installed in
close proximity to a premises’ entry door equipped with a Magnetic Sensor and defined as
Entry/Exit, where such device might trigger an alarm within the delay period.
Notes: The Walk-Through configuration may be enabled, per device, for the
security devices (PIR/IPD/MGL).
This feature will become operational only if another security device in the
system is configured as Entry/Exit.
Configuring a device as Walk-Through with no other device configured as
Entry/Exit is feasible, but will have no functional value in the system.
A single device may be defined as either Entry/Exit or Walk-Through.