3.11.2.1. Flood Detector Positioning Recommendations
For optimal safety, the following factors must be taken into consideration when selecting the
Flood Detector mounting position:
A flat vertical surface for the transmitter, horizontal for the sensor.
Attach the Flood Detector (applicable for both parts) to a surface that is clean, dry, flat
and smooth.
The Flood Detector must be mounted within 700m (2300ft) (open air nominal) of the
CCU.
Typically, the Transmitter Unit will be attached onto a nearby wall or furniture while the
Sensor Unit is built for installation directly onto the potentially flooded zone.
3.11.2.2. Installing the Flood Detector Transmitter Unit with Screws
1. Release the Flood Detector Transmitter Unit base by inserting a coin into one of the edge
slots, as demonstrated in the Figure 117 above, and twist it to open the cover.
2. Use a flat screwdriver to remove the punch-outs 1 and 2 (see Figure 118 below).
Figure 118: Flood Detector Transmitter Unit Base with Screws
2
1