Instruction Manual

Page 24
500IH-I05-020320
Further information on the requirements of the Clean Air Act can be found here:
http://smokecontrol.defra.gov.uk/
Your local authority is responsible for implementing the Clean Air Act 1993
including designation and supervision of smoke control areas and you can
contact them for details of Clean Air Act requirements
“The ESSE Bakeheart and Warmheart Cooking Stoves have been recommended
as suitable for use in smoke control areas when burning dry wood logs”
Technical Information
Nominal heat output
5.0kW
Minimum chimney
draught
12Pa
Net efficiency
77.3%
Seasonal efficiency
67.3%
ERP rating
A
Energy index
102
Combustion air
requirements
29m
3
/h
Mean flue gas
temperature
253
o
C
Weight of appliance
Bakeheart:
Warmheart:
192 kg
154 kg
Flue gas mass flow
5.4g/s
Mean NO
X
82 Nmg/m
3
Mean CO
0.08%
Dust emissions
23 Nmg/m
3
Mean C
n
H
m
54 Nmg/m
3
CHIMNEY AND FLUE INFORMATION
The successful operation of the cooking appliance relies on the adequate
performance of the chimney to which it is connected. The following chimney
guidelines must be followed:
o It should meet the requirements laid out in BS EN 15287-1:2007 design,
installation and commissioning of chimneys.
o It should have an internal cross section of no less than 320cm2 (200mm
dia.) (If a flue liner is used, it should be 150mm (6’’) diameter and be made
of suitable material for burning wood). A Flue with a diameter of 150mm
(6’’), is required to connect to the cooker.