Network Setup.
3.7.1 Alarm setup
Move the cursor to the “Alarm Setup” option (the icon is surrounded by a yellow
frame to indicate selection), and press “Enter” to enter the setup screen of this
option, as shown below:
I/O state alarm: Each channel corresponds to an I/O state alarm, i.e., when the
alarm input of a channel is valid, the alarm record of the corresponding channel
will be started.
Normal On: The external alarm circuit is open at ordinary times, and closed
when there is an alarm.
Normal Off: The external alarm circuit is closed at ordinary times, and open
when there is an alarm.
Note: When an alarm is produced, a red letter “I” will be displayed above the
corresponding channel.
Harddisk failure alarm: On: When the system cannot identify the harddisk, an
alarm will be generated, and a red mark “H” will be displayed at the bottom left
corner of Channel 1 in the lower part of the Video Preview screen.
Not enough space of harddisk: On: When the remaining space of the harddisk is
less than 500M, the lower part of the Video Preview screen will display: “The
space of the harddisk is not enough. Please change the disk after shutdown.”
Video loss alarm: On: When the video of a certain channel is lost, this channel
will display in the lower part of the Video Preview screen: “Video Loss”.