Operating instructions
20
INSTALLER
INFORMATION
Clearances to Combustibles
Minimum Clearance to Combustible Materials
ENCLOSED SIDE WALL 1.75"
ENCLOSED BACK WALL NCR*
ENCLOSED CEILING 4"
ECLOSED FRONT WALL 24" From top of the glass
EXPOSED SIDE WALL 8" From side of the glass
VENT ENCLOSURE 1"
EXTERIOR SOFIT 16"
*NCR STANDS FOR NO CLEARANCE REQUIRED; YOU MAY USE COMBUSTIBLE CONSTRUCTION
MATERIALS IN DIRECT CONTACT WITH THE APPLIANCE ON THESE SURFACES.
When the appliance is installed directly on carpeting, tile or other combustible material other
than wood flooring, the appliance shall be installed on a metal or wood panel extending the full
width and depth of the appliance. Specified clearances shall be maintained from the top surface
of carpeting, tile, etc.
Figure 28: Minimum Distance
From Top Of The Glass To Ceiling
Figure 29: Front and Side Definitions
Front of the appliance is an open side of the combustion chamber
covered with the glass.
Facing the front of the appliance side from left is the left side of the
appliance and side from right is the right side of the appliance.
LEFT SIDE
RIGHT SIDE
FRONT