Installation manual

Esprit 748+ 1
Part 1: Introduction
1.1 About This Manual
This manual provides all the information you will need to understand panel operation, features and functions. If you are familiar
with other security control panels, we recommend that you read this manual at least once to familiarize yourself with panel
features and programming. Please refer to the index for a complete list of this manual's contents.
The following terminology is used throughout this manual:
[ ] = indicates a key on the keypad
[ ] = indicates a key on the keypad must be pressed
= indicates a warning or important note
italic = indicates data that must be entered, reference to a section in the manual, or an example
SMALL CAPS” = indicates terminals or LEDs that are located on the control panel, keypad, etc.
1.2 Features
Improved Lightning Protection
New and Innovative Dialer Circuit
748+ : 24 zones (12 on-board inputs with ATZ = 24 zones including 2 keypad zones)
Powerful 16-bit RISC processor with built in analog to digital converters
User-friendly programming
"False Alarm Prevention" features such as: Intellizones, Auto Zone Shutdown, Beep on Exit Delay, Programmable
Delay Before Alarm Transmission, and Recent Closing Report
2 Flexible Partitions
High-Speed Communication Formats
256 Event Buffer with time and date stamp
2 fully programmable outputs (PGMs) Upload & Download capability with Espload Software
Alarm Relay
48 User Codes + 1 Master Code + 1 Installer Code
Telephone Line Supervision
3 keypad activated panic alarms
Regular Arming, "Stay" Arming, "Double Stay" Arming, Force "Away" Arming, "One- Key” Regular Arm, "One-Key" Stay Arm,
"One-Key" Exit & Re-arm, "Auto Arming", Key Switch
1.3 Specifications
Battery Charger: 360mA with dynamic Battery test.
Aux. Power: Two auxiliary outputs rated at 1A each. Fuseless electronic shutdown at 1.1A, automatic restore
Bell Out: 1A, Fuseless electronic shutdown at 3A, automatic restore
AC input: 16.5 VAC, 40VA min. (recommended: 75VA), 50 - 60Hz
PGM outputs: N.C. or N.O to ground, 50mA Max.
Serial Data Output: (1200, 1, N) for use with accessory modules (not UL systems).