11.12.5 Maximum Auxiliary Current - Key [6]
The illumination of the [6] key indicates that the auxiliary current has exceeded 1A. This will cause automatic shutdown
of the auxiliary output. After opening the short or reducing the load, the panel will restore power to the auxiliary output
following the dynamic battery test (approximately 60 seconds).
11.12.6 Communicator Report Failure - Key [7]
If the control panel was unsuccessful when attempting to communicate with the monitoring station computer or the
Espload software the [7] key will illuminate.
11.12.7 Timer Loss - Key [8]
The illumination of the [8] key indicates that the control panel’s internal clock must be re-programmed. To re-program
the timer press:
[
ENTER] + (Installer, Master or User 1 Code) + [MEM] + 2 digits (00 to 23) representing hours + 2 digits (00 to 59)
representing minutes + [ENTER]
11.12.8 Tamper/Zone Wiring Failure - Key [9]
If the Tamper/Wire Fault Recognition Options (see section 10.7) are enabled, the [9] key will illuminate to indicate a
short or cut on a zone input. In order to provide line short recognition the zone connections must have EOL resistors
(see Zone Input Terminal Connections sections 2.8 to 2.10).
11.12.9 Telephone Line Monitoring - Key [10]
If the Telephone Line Monitoring (TLM) feature (see section 10.1) is enabled, the [10] key will illuminate to indicate
that the control panel has not detected the presence of a telephone line for 30 seconds.
11.12.10 Fire Trouble - Key [11]
The illumination of the [11] key indicates a tamper on zone 3, if identified as a fire zone (see "24 Hour" & Fire Zones in
section 7.5).
11.13 Key Access Programming
This method allows for quick programming of features without entering addresses or section numbers. The following features are
programmed using the installer code as well as the master code and user 1 codes.
Auto Arm Time: for details see section 8.1.1
Panel Time: for details see section 10.5
Manual Test Report: for details see section 6.8
Call Espload: for details see section 5.5
Answer Espload: for details see section 5.6
Cancel Communication: for details see section 5.7
Installer Test Mode: for details see section 10.9