Installation manual
Esprit 748+ 39
"Tamper/wire" disabled
Tamper/wiring failure recognition is disabled. Not permitted on UL listed systems.
"Trouble" enabled
Tamper/wiring failure will generate a trouble indicator (key [9]) and a trouble report code (see Tamper/Trouble Codes in section
6.6.6.) when the system is disarmed.
"Silent alarm" enabled
Tamper/wiring failure will generate a trouble indicator (key [9]), a trouble report code (see Tamper/Trouble Codes in section
6.6.6.) and a silent alarm (no bells/sirens)
"Audible alarm" enabled
Tamper/wiring failure will generate a trouble indicator (key [9]), a trouble report code (see Tamper/Trouble Codes in section
6.6.6.) and an audible alarm.
When the zone definition is "24 hour", the tamper definition follows the audible/silent alarm definition of the "24
hour" zone.
10.8 Tamper Bypass Options
Feature Select Programming
D
Address 090, key [6]
With this option enabled, the control panel will not generate an alarm if a tamper is detected on a bypassed zone while the
system is armed. With this option disabled, the control panel will generate an alarm if a tamper is detected on a bypassed zone
while the system is armed.
Key [6] "Off": Arm the system if Tamper on Bypassed Zone
Key [6] "On": Do not arm the system if Tamper on Bypassed Zone
[
ENTER] + Installer Code + [10] [9] [10] + [6] On/Off + [ENTER]
10.9 Installer Test Mode
Key Access Programming
D
key [8]
The "Test Mode" will allow you to perform walk tests where the bell or siren will squawk, to indicate opened zones. To enter or exit
the control panel "Test Mode" press:
[
ENTER] + Installer Code + [8] to enable; press [8] again to disable
10.10 Exclude Power Failure From Trouble Display
Feature Select Programming
D
Address 090, key [2nd]
Default: Disabled
Excludes the Power Failure, key [2], from the Trouble Display (see section 11.2).
10.11 Audible Trouble Warning
Feature Select Programming
D
Address 090, key [9]
Default: Disabled
Trouble conditions will emit an intermittent "beep" on the keypad. To silence the trouble warning, press the [
TRBL] key.
10.12 Power Down Reset
Performing a power down reset will set the installer and master codes to factory default. Values entered at addresses 008-043,
062-124, 300-527, and all user codes will be erased ([2ND], [2ND]). Programmed values for all other addresses do not change. To
perform a reset, the installer lock must be disabled. To perform a power down reset perform the following:
1) Verify installer lock is disabled (see section 3.5)
2) Remove the battery and AC power from the control panel.
3) Set the reset jumper to on by placing a jumper on the reset pins of the control panel.
4) Re-connect the AC and battery power to the control panel.
5) Wait 10 seconds and remove the jumper.