Key [4] "off" = Panic 1 silent
Key [4] "on" = Panic 1 audible
Key [5] "off" = Panic 2 silent
Key [5] "on" = Panic 2 audible
Key [6] "off" = Panic 3 silent
Key [6] "on" = Panic 3 fire alarm
[
ENTER] + Installer Code + [10] [8] [8] + [1] to [6] On/Off + [ENTER]
Silent operation:
When using the panic keys or the PS1, the control panel will emit a single confirmation beep. The control panel will transmit the
event codes programmed at addresses 513, 514, and 515. The alarm will latch (no audible alarm) and the "armed" light on the
keypad will flash until the system is disarmed by a valid User code.
Audible operation:
Same as silent operation, except the alarm output (bell/siren) will activate until the system is disarmed by a valid User code or
until the Bell Cut-Off Time (see section 8.11) elapses.
Fire operation:
Same as audible operation except that bell/siren output will be pulsed (see Fire Alarm Output Figure on page 28).
10.5 Panel Time
Key Access Programming
D
key [mem]
To program the current time into the control panel press:
[
ENTER] + (Installer, Master, or User 1 Code) + [MEM] + 2 digits representing hours (00-23) + 2 digits representing minutes (00-59)
10.6 Time Correction
Streamline - Section 09
D
Hexa Programming - Address 037
If you notice a gain or loss in the control panel time, calculate the average gain or loss per day; select the "opposite" amount from
the Time Correction table in order to automatically correct the time setting every 24 hours.
Example: The control panel loses 4 minutes per month, representing an average loss of 8 seconds per day. Therefore, program
[2] (plus 8 seconds) as the second digit in address 037 to compensate for the 8-second loss.
10.7 Tamper/Wire Fault Recognition Options
Feature Select Programming
D
Address 088, keys [10] to [11]
If the control panel detects an open or a short on a zone when the system is armed, regardless of the tamper/wire settings it will
always generate an alarm and trouble indicator (key [9]). Alarms will be audible or silent depending on individual zone definitions.
If an open or short occurs on a disarmed system, the control panel will generate an incident depending on the following settings:
Table 13 - Time Correction Table
(address 037 2nd digit)
[2
ND] - No adjustment [4] - Plus 16 seconds [8] - Minus 4 seconds [AWAY]/[FORCE] - Minus 20 seconds
[1] - Plus 4 seconds [5] - Plus 20 seconds [9] - Minus 8 seconds [
BYP] - Minus 24 seconds
[2] - Plus 8 seconds [6] - Plus 24 seconds [0] - Minus 12 seconds [
MEM] - Minus 28 seconds
[3] - Plus 12 seconds [7] - Plus 28 seconds [
STAY] - Minus 16 seconds [TBL/TRBL] - Minus 32 seconds
Table 14 - Tamper Recognition Option
Key [10 (0)] Key [
STAY]
OFF OFF - Tamper/Wire Fault disabled
OFF ON - Trouble Indicator enabled
ON OFF - Silent Alarm enabled
ON ON - Audible Alarm enabled