Installation manual

34 Reference & Installation Manual
8.9 Alarm Transmission Delay
Decimal Programming
D
Address 059
This time limit, set between 5 and 63 seconds, is the delay period before reporting an alarm to the monitoring station after an
alarm condition. During this period, disarming the system will cancel all pending alarms and send the restore codes.
Programming 000-004 in this address disables this feature. Maximum 30 seconds on UL listed systems.
[
ENTER] + Installer Code + [10] [5] [9] + 3-digit decimal value (005-063) + [ENTER]
8.10 Silent Zones & Silent Panics Option
Feature Select Programming
D
Address 086, key [9]
If the [9] key is on, silent zones or silent panics only transmit a report to the monitoring station. The system will not indicate an
alarm and will not have to be disarmed.
Although, the control panel can still activate a PGM. If a keypad panic has been defined as audible, the control panel will override
this option.
Key [9] "Off": Silent Zones & Silent Panics generate a silent alarm
Key [9] "On": Silent Zones & Silent Panics generate a report only
[
ENTER] + Installer Code + [10] [8] [6] + [9] On/Off + [ENTER]
8.11 Bell Cut-Off Time
Decimal Programming
D
Address 052
Default: 5 minutes
After an audible alarm, the bell or siren will stop after the programmed time has elapsed.
[
ENTER] + Installer Code + [10] [5] [2] + 3-digit decimal value (001-255) minutes + [ENTER]
8.12 Code Priority
Feature Select Programming
D
Address 062-078, [all] keys
In order for a user to arm a partitioned system, to "Stay" arm, to "Away" arm or to manually bypass zones, the user must be given
code priority. Using the "Feature Select Programming Method", identify which arming method each user can use. For more
information on arming/disarming methods please refer to section 11. Also refer to the “Programming Guide” for additional
information.
Partitioning Disabled:
Addresses 062-066: Selected keys indicate which user codes can activate "Stay" arming.
Addresses 068-072: Selected keys indicate which user codes can activate "Away" arming.
Addresses 074-078: Selected keys indicate which user codes can "Bypass" zones.
Partitioning Enabled:
Addresses 062-066: Selected keys indicate which user codes can arm “System A".
Addresses 068-072: Selected keys indicate which user codes can arm “System B".
Addresses 074-078: Selected keys indicate which user codes can "bypass" zones.