Installation manual
Esprit 748+ 33
Key [7] "Off": "One Key" Regular Arming Disabled
Key [7] "On": "One Key" Regular Arming Enabled
[ENTER] + Installer Code + [10] [8] [8] + [7] On/Off + [ENTER]
8.4 One-Key Stay/System A Arming
Feature Select Programming
D
Address 088, key [8]
Default: Disabled
Press and hold the [11] key for 2 seconds to "Stay" arm the system if partitioning is disabled. If the system is
partitioned, the control panel will arm System "A".
Key [8] "Off": "One Key" Stay/System A Arming Disabled
Key [8] "On": "One Key" Stay/System A Arming Enabled
[
ENTER] + Installer Code + [10] [8] [8] + [8] On/Off + [ENTER]
8.5 Arming using a keyswitch
Feature Select Programming
D
Address 086, key [2] & [3]
Default: Disabled
The User can use a keyswitch to "Stay" arm or "Regular" arm/disarm the system. If the system is ready and the button is pressed
the system will arm. Pressing the button again will disarm the system. The keyswitch will not disarm a “Stay” armed system in
alarm. Refer to section 2.7 for installation of a keyswitch.
[
ENTER] + Installer Code + [10] [8] [6] + [2] & [3] On/Off + [ENTER].
8.6 Bell Squawk
Feature Select Programming
D
Address 086; key [mem]
Default: Disabled
With this feature enabled, the bell or siren will emit a half-second "squawk" upon arming and two half-second "squawks" upon
disarming.
Key [mem] "Off": Bell Squawk Disabled
Key [mem] "On": Bell Squawk Enabled
[
ENTER] + Installer Code + [10] [8] [6] + [MEM] On/Off + [ENTER]
8.7 Exit Delay
Decimal Programming
D
Address 049
Default: 60 seconds
Exit Delay applies to all zones. This option determines how much time the user has to leave the protected area before the system
arms after entering a valid access code. You can program the Exit Delay from 001 to 255 sec.
[
ENTER] + Installer Code + [10] [4] [9] + 3 digit decimal value (001-255) + [ENTER]
8.8 Beep on Exit Delay
Feature Select Programming
D
Address 088, key [12]
Default: Disabled
With this feature enabled, the keypad will emit an intermittent "beep" during the programmed exit delay period (except when in
"stay" arming). The frequency of intermittent beeps increases during the last 10 seconds of the exit delay period. For more
information on Exit Delay refer to section 8.7.
Key [12] "Off": Beep on Exit Delay Disabled
Key [12] "On": Beep on Exit Delay Enabled
[
ENTER] + Installer Code + [10] [8] [8] + [12] On/Off + [ENTER]
Table 9 - Keyswitch Arming
Key [2] Key [3] Function
OFF OFF Disabled
ON OFF Disabled
OFF ON Full Arming
ON ON Stay Arming*