Installation manual

24 Reference & Installation Manual
511 - TLM Trouble Restore: Telephone line has restored after the TLM (see section 10.1) has detected
the loss of a telephone line.
6.6.8 Special Codes
Streamline - Sections 64 to 67
D
Hexa Programming - Addresses 512-527
Each address represents a special condition in the system. When one of these special conditions occur, the control
panel will report the event code associated with the address.
512 - Test Report: The test report has been activated either manually (see section 6.8) or automatically
(see section 6.7).
513 - Panic 1: Keys [1] and [3] or a PS1 is pressed to activate a Panic 1 alarm
514 - Panic 2: Keys [4] and [6] are pressed to activate a Panic 2 alarm
515 - Panic 3: Keys [7] and [9] are pressed to activate a Panic 3 alarm
For more information on Keypad Panic Options see section 10.4
516 - Late To Close: "Timed" Auto Arming is enabled (see section 8.1) and the system has not
automatically armed itself at the specified time.
517 - No Movement: "No Movement" Auto Arming is enabled (see section 8.2) and no movement has
occurred for the designated amount of time.
518 - Partial Arming: Whenever the system is "Away" armed, "Stay" armed, or armed while one or more
zones are bypassed.
519 - Recent Close: An alarm occurs shortly after the system has been armed, refer to Recent Close
Delay in section 6.10.
520 - Duress: The Duress feature is enabled (see section 3.4) and a User disarms the system using the
User Code #48.
524 - Log-In (Espload): Espload software is used to communicate with the Control Panel.
525 - Program Change: The installer code is used to enter the programming mode
521 to 523 - Reserved for Future Use
526 to 527 - Reserved for Future Use
6.7 Auto Test Report
Decimal Programming
D
Addresses 046-048
Default: Auto Test Report Disabled
The report code programmed at address 512 will be reported to the monitoring station after the number of days programmed at
address 046 and the time programmed at address 047 (hours) and 048 (minutes) has elapsed. To disable this feature, program
000 at address 046. Also note that if [2nd][2nd] is programmed at address 512 nothing will be reported.
[
ENTER] + Installer Code + [10] [4] [6] + 3 digits (days) + [10] [4] [7] + 3 digits (hours) + [10] [4] [8] + 3 digits (minutes) + [ENTER]
6.8 Manual Test Report
Key Access Programming
D
key [byp]
Activating the manual test report will send the Event Code programmed at address 512 to the Monitoring Station.
[
ENTER] + (Installer, Master, or User 1 Code) + [BYP] + [ENTER]
6.9 Power Failure Report Delay
Decimal Programming
D
Addresses 054
Default: 30 minutes
After a power failure, the control panel will delay transmission of the event code programmed at address 499 by the
period programmed at this address (001 to 255 minutes).
[
ENTER] + Installer Code + [10] [5] [4] + 3-digit decimal value (001-255) + [ENTER]
6.10 Recent Close Delay
Decimal Programming
D
Addresses 060
Default: Recent Close Delay Disabled
The system will transmit the recent close event code programmed at address 519 if after arming the system, an
alarm occurs within the period programmed at this address (001 to 255 minutes). Program 000 into address 060 tO
disable this feature.
[
ENTER] + Installer Code + [10] [6] [10] + 3-digit decimal value (001-255) + [ENTER]