Installation manual
14 Reference & Installation Manual
5) Enter 3-digit data (decimal) value; after entering data you do not need to press [ENTER], the software will automatically save the
data into the selected address
6) Return to step 2 to continue programming or press [
CLEAR] to exit programming mode
4.2.4 Feature Select Programming
Addresses 062 to 126 are programmed using the Feature Select Programming method. In this method, every key in
each address on the keypad represents an option or feature. Pressing a key will display it on the keypad and pressing
it again will extinguish the key. The On/Off status of each key determines the selected feature. To program using the
Feature Select Programming method:
1) Press [
ENTER] + Installer Code
2) The [
ENTER] key will flash to indicate you are in programming mode
3) Enter 3-digit address (062-126)
4) After entering the address, the keypad will display the feature selection status. The On/Off status of the keys
determines the selected features as described in the "Programming Guide" and in the appropriate sections of this
manual. Turn the keys On/Off by pressing the appropriate key until the desired options are set. Then press the [
ENTER]
key to accept, there will be a confirmation "beep" indicating the options have been accepted. The [enter] key will flash
to indicate that the software is awaiting the next address entry
5) Return to step 3 to continue programming or press [
CLEAR] to exit programming mode
4.2.5 Key Access Programming
This method allows for quick programming of features without entering addresses or section numbers. The following
features are programmed using the installer code as well as the master and user 1 codes.
• Installer Test Mode: see section 10.9
• Auto Arm Time: see section 8.1.1
• Answer Espload: see section 5.6
• Call Espload: see section 5.5
• Cancel Communication: see section 5.7
• Manual Test Report: see section 6.8
• Panel Time: see section 10.5