User Manual
Table Of Contents

computer radio control system
3.1 Voltage supply
When designing the on-board wiring for your project, always pay
attention to the voltage input range of your receivers and servos.
You can connect supply voltage to the Duplex receivers as
follows:
- directly from the batteries
- via a BEC voltage regulator (either contained in speed
controllers or self contained)
The supply may be connected to the Duplex receivers via:
- the throttle channel (when applying speed controllers with BEC)
- a free receiver output.
- a Y-cable to any arbitrary receiver output
- the MPX connector for receivers with the EPC label which are
equipped with a power supply connector
3.2 Operation
We recommend that you switch on the transmitter first and then
subsequently the receiver. The transmitter confirms the switching-
on of the receiver with an acoustic signal. When switching off the
system we recommend that you switch off the receiver first and
then subsequently proceed with switching-off the transmitter.
3 Installation
EN
5
JETI model s.r.o.
Lomená 1530, 742 58 Příbor
Czech Republic - EU
www.jetimodel.com
www.jetimodel.de
info@jetimodel.cz
Duplex-System EX:
• Transmitter modules
• Receivers
• Telemetric sensors
• Compatible accessories
• Display units
Duplex-System EX:
• Sendermodule
• Empfänger
• Telemetrische Sensoren
• Kompatibles Zubehör
• Abbildungseinheiten