User Manual

computer radio control system
Classic setup of a single receiver
(for any analogue/digital servos)
- servo impulses are generated on servo outputs
- each output can be assigned to one of the groups from A to H
- servo outputs assigned to one group are generated at the same
time
- between two consecutive servo groups there is a delay of 2.5ms
8 Examples of Rx setup
SignalFaultDealy
OutputPeriod
Rx mode
1.5s
17 ms
Normal
Classic setup of a single receiver (for digital servos)
SignalFaultDealy
OutputPeriod
Rx mode
1.5s
Auto
Normal
The second receiver as a backup (clone mode)
- monitors existing connection between the transmitter and the
receiver in "Normal" mode
- does not support telemetry (or an indication of the signal
strength)
- works in receiving direction only, it never transmits
- any number of receivers in Clone mode can be operated
simultaneously
FailSafe
SignalFaultDealy
OutputPeriod
Rx mode
Disabled
1.5s
17 ms (or Auto)
Clone