User's Manual

6.
Product Handling
6. Product Handling
6.1 Storage Condition
The products sealed in Moisture Barrier Bag (MBB) should be stored in a noncondensing atmospheric environment
of < 40 °C/90%RH.
The module is rated at moisture sensitivity level (MSL) 3.
After unpacking, the module must be soldered within 168 hours with factory conditions 25±5 °C/60%RH. The
module needs to be baked if the above conditions are not met.
6.2 ESD
Human body model (HBM): 2000 V
Charged-device model (CDM): 500 V
Air discharge: 6000 V
Contact discharge: 4000 V
6.3 Reflow Profile
Figure 6: Reflow Profile
Note:
Solder the module in a single reflow. If the PCBA requires multiple reflows, place the module on the PCB during the final
reflow.
Espressif Systems