Repair manual

41
5 / Repair Instructions
Figure 10
~ Solenoid valve
Ä =Connection of the “Solenoid valve” cable section to the
control unit, slot “D”
Removing the solenoid valve
(see Figure 10 and Drawing 26)
Take off the hood.
Remove burner.
If necessary, check the solenoid valve with the test unit for
burner head (see below).
Pull out “Solenoid valve” cable section at the control unit,
slot “D”.
Loosen hexagonal nut from the solenoid valve.
Remove solenoid valve coil.
Unscrew magnet.
Please note!
During installation of the heater, lay the cable sections as
shown in Figure 10.
Drawing 26
~ Magnet
Ä Solenoid valve coil
Checking the solenoid valve with the test unit for
burner head
Remove all connectors from the control unit.
Connect test unit for burner head.
Press “MV” button ---> solenoid valve should click. If it
does not, replace solenoid valve.
~
Ä
1
2
3
~
Ä