Figure 10
~ Solenoid valve
Ä =Connection of the “Solenoid valve” cable section to the
control unit, slot “D”
Removing the solenoid valve
(see Figure 10 and Drawing 26)
• Take off the hood.
• Remove burner.
• If necessary, check the solenoid valve with the test unit for
burner head (see below).
• Pull out “Solenoid valve” cable section at the control unit,
slot “D”.
• Loosen hexagonal nut from the solenoid valve.
• Remove solenoid valve coil.
• Unscrew magnet.
Please note!
During installation of the heater, lay the cable sections as
shown in Figure 10.
Drawing 26
~ Magnet
Ä Solenoid valve coil
Checking the solenoid valve with the test unit for
burner head
• Remove all connectors from the control unit.
• Connect test unit for burner head.
• Press “MV” button ---> solenoid valve should click. If it
does not, replace solenoid valve.
~
Ä
1
2
3
~
Ä