Repair manual
39
Removing the fuel atomizer nozzle (see Figure 6)
• Take off the hood.
• Remove burner.
• Remove ignition electrodes.
• Unscrew fuel atomizer nozzle from the nozzle holder.
Please note!
• When installing the fuel atomizer nozzle, do not touch the
nozzle opening.
• Following installation of the fuel atomizer nozzle, check the
position of the ignition electrodes and adjust as necessary.
• Tightening torque for fuel atomizer nozzle 16 +1 Nm.
5 / Repair Instructions
Drawing 26
~ Ignition electrodes
Ä Reference gauge
Figure 6
~ Fuel atomizer nozzle Å = Baffle plate
Ä Ignition electrodes Ç Flame monitorr
Removing the ignition electrodes
(see Figure 5 and Drawing 26)
• Take off the hood.
• Remove burner.
• Remove ignition electrodes from ignition spark generator.
Following installation, check the position of the ignition
electrodes and adjust as necessary.
• Attach the reference gauge to the nozzle and push as far
as the limit stop.
• Check the electrode position. The points of the electrodes
should be touching the square-shaped surfaces of the
reference gauge. If necessary, carefully bend the electrode
points until they are touching the square surfaces of the
reference gauge.
Figure 5
~ Ignition electrodes
Please note!
• The insulation of the ignition electrodes must not be
damaged.
• When measuring the distance between the electrodes
do not touch the fuel atomizer nozzle opening.
• The reference gauge is enclosed with the spare parts.
~
Ä
Å
Ç
~
Ä
~