Repair manual
18
Template
for holes
3 / Installation
Water pump - standard model
Principal measurements and permissible installation positions
Installation of the water pump
The water pump must be installed at the lowest point in the
water circulation system, taking into account the installation
position - see diagrams.
Transfer the four fastening holes for the water pump holder to
the mounting surface - as shown in the diagram - and drill.
Attach the water pump to the vehicle with the holder.
Bus 2000 water pump
Principal measurements and permissible installation positions
Delivery curve
Template
for
holes
Delivery curve
Drawing 11
Please note!
• No shutoff valves may be inserted in the water hose for the
water pump (intake side).
• The surface in contact with the water pump holder must
be flat.
219
100
55
85
90
112
98
85
ø 9 (4x)
0,1
0,2
0,3
0,4
0,5
0,6
0,7
P
[bar]
123456789
V
[10
3
l/h]
24V
55
85
ø 9 (4x)
Drawing 12
0,1
0,2
0,3
0,4
0,5
P
[bar]
123456789
V
[10
3
l/h]
0,6
0,7
0,8
0,9
1,0
24V
240
98
113
153
120
10
90
85
85
120
120
Pump components can be
rotated by 3 x 120° to the motor part.