Repair manual
17
3 / Installation
Permissible installation positions and
attachment of the HYDRONC
The HYDRONIC should if possible be installed in the normal
position.
To do this, transfer the 4 fastening holes and the through-hole
for the exhaust outlet - as shown in the diagram - to the
mounting surface and drill.
Fasten the HYDRONIC to the vehicle with the two mounting
supports.
Permissible installation positions and template for holes for the
HYDRONIC - standard model and compact model
Please note!
• The support surface for the two mounting supports of the
HYDRONIC must be flat.
• Depending on the installation conditions, the HYDRONIC
can be inclined, as shown in the diagrams.
During operation of the heater a deviation from the normal
position - caused by the incline of the vehicle - of up to +15º
in all directions is possible.
Compact model - must be installed in level position with the
deviations shown in the diagram.
Drawing 10
15°
15
°
5°
5°
15°
15°
5°
5°
320
82
Ø 9 (4x)
Ø4,5 at M4
Ø2,9 at B3,9
150
82
75
Hole template for the HYDRONIC - standard model
and compact model
Standard model
• Must be installed in level position with the deviations
shown in the diagram
• Can also be installed in vertical installation position
without any deviations.