Repair manual
15
Regulation!
• Installation in the driver‘s cab or passenger compartment
of buses containing more than eight seats in addition to the
driver‘s seat is not permitted.
Please note!
• Mount the HYDRONIC below the minimum cooling water
level (expansion tank, radiator, vehicle heat exchanger).
• Further information on installation (e.g. for boats and ships)
is available from the manufacturer on request.
• For installation of the HYDRONIC in a case, see page 16.
3 / Installation
1 HYDRONIC
2 Water pump
3 Tank connection
4 Vehicle engine
5 Front heater
6 Roof air ducts
7 Roof heater
8 Floor heater
Drawing 7
Installation position
The heater should be installed as low down as possible in
the vehicle, e.g. in the engine compartment or in a stowage
area.
This will ensure that the heater and water pump are
automatically ventilated.
Other installation positions are also permitted as long as
they comply with the installation requirements stated in these
Installation Instructions.
When choosing where to install the heater, care must be taken
to ensure that there is sufficient space to disassemble the
hood (130 mm) and the flame pipe (375 mm).
All openings towards the outside must be splash-proof.
Example of a HYDRONIC installation in a bus