Operating instructions

27
MMaaiinntteennaannccee,, TTrroouubblleesshhoooottiinngg && RReeppaaiirrss
FFaauulltt CCooddee FFaauulltt DDeessccrriippttiioonn CCaauusseess // RReeppaaiirr FFaauulltt SSiiggnnaall // FFllaasshhiinngg CCooddee
064 Open circuit - flame sensor Flame sensor signals temperature value outside
measurement range. Check the connecting leads (0.35
green). Impedance between terminals 10 and 12 of the
065 Short circuit - flame sensor control unit (internal plug): greater than 50 kohms (in the
event of interruption) less than 100 ohms (in the event
of short-circuit). Flame sensor values:
900 ohms at -25°C, 1100 ohms at +25°C.
071 Open circuit - overheat sensor Overheat sensor signals temperature value outside
measurement range. Check the connecting leads (0.35
072 Short circuit - overheat sensor blue). Impedance between terminals 5 and 8 of the
control unit (internal plug): greater than 700 kohms
(in the event of interruption) less than 100 ohms (in the
event of short-circuit). Overheat sensor values:
150 kohms at -25°C, 10 kohms at +25°C.
090 Control unit defect (internal fault) Internal control unit error in microprocessor/memory
detected. Replace control unit.
093 Control unit defective(RAM error)
094 Control unit defective(EPROM fault)
097 Control unit defective (power failure)
88 sseeccoonnddss