Operating instructions

The 7 Day Timer has been
designed to provide a simple
means to control the operation
of the heater system and to
include diagnostics capability.
This timer connects to the diag-
nostic circuit of the heater. The
timer then displays any heater
fault codes in three digit number
form automatically. The timer
allows for pre-selection of turn
on time, up to 7 days in
adv
ance, as well as an option for
run times up to 2 hours before
automatically turning off. In addi-
tion, there is an on/off switch for
manual operation. By default the
timer is pre-set by Espar to oper-
ate for two hours.
1 Mount bezel into dash and
insert timer or use Espa s
optional mounting bracket and
secure to dash.
2 Use hardware supplied for
connections.
3 Connect the switch harness to
the connector at the heater and
run harness to switch location.
(Harness should be neatly rout-
ed and secured under dash-
board).
4 Cut harness to length and ter-
minate wires. Attach using con-
nectors provided.
1 Time set
2 Preheat time set
3 Heater On
4Backward scan
5Forward scan
6 Memory location
7 Time and day display
8 Air temperature display
(optional)
9Heater On symbol
10 Temperature set
(air heater only)
Note: Upon connection to power the
entire timer display will begin to flash.
The heater will not function until the
time is programmed.
Setting Time and Weekday
Push button once. 12:00 will begin to flash (this will occur upon
initial hook up to power).
Using or set the present time of day (24 hour clock).
When the time stops flashing the time has been stored.
The weekday will now begin to flash.
Use or to set the present weekday.
When the weekday stops flashing the weekday has been stored.
When the vehicle ignition is turned on the time display will appear
.
When the vehicle ignition is turned
off the timer display will go off
after 15 seconds.
Coolant Heater
Air Heater
14
IInnssttaallllaattiioonn PPrroocceedduurreess
PPuusshh//PPuullll SSwwiittcchh
MMoouunnttiinngg BBrraacckkeett && BBeezzeell
P/N 25 1482 70 01 00
Mounting Bracket
Bezel
77 DDaayy TTiimmeerr IInnssttrruuccttiioonnss
OOppeerraattiinngg IInnssttrruuccttiioonnss
Mount switch in a location where it is easily accessible
Mount using hardware supplied
Connect the switch harness to the connector at the heater
and run the harness to the switch location
Cut harness to length at the switch and install terminals
Connect wiring as described below
14.5mm
9/16”
K (15)
15 (K)
31
Ø
Ø
NNoottee::
Wired described the switch light glows when
pulled out and is off when pushed in.
Brown- 31 Power from battery “-”
Red- K(15) Power from battery “+”
Yellow-15(K) Switch control to the heater
Blue/White Diagnostic from heater (disregard - tape end
and tie off to the side)
P/N CA1 00 003 (12v)
P/N CA1 00 004 (24v)