Specifications

SECTION 3 Installation
ESP-600C Plasma Power Source -
3-6
3.5.2 Output Connection Procedure
1. Remove access panel on the lower front of the
power source.
2. Thread output cables through the openings at
the bottom of the front panel or at the bottom of
the power source immediately behind the front
panel.
3. Connect cables to designated terminals
mounted inside the power source using UL
listed pressure wire connectors.
4. Replace panel removed during the first step.
3.6 Parallel Installation
Two power sources may be connected together to
extend the output current range.
CAUTION
Parallel power source start currents
exceed recommended amounts when
cutting below 100A.
Use Only One Power Source For Currents
Below 100A.
We recommend disconnecting the negative
lead from the secondary power source when
changing to currents below 100 amperes.
This lead should be safely terminated
(insulated) to protect against electric shock.
Access Panel