Specifications
SECTION 3 Installation
ESP-600C Plasma Power Source -
3-4
NOTICE
3.4.2 Input Conductors
• Customer supplied
• May consist either of heavy rubber covered
copper conductors (three power and one
ground) or run in solid or flexible conduit.
• Sized according to the chart.
Input conductors must be terminated with
ring terminals.
Input conductors must be terminated with ring
terminals sized for ½" hardware before being
attached to the ESP-600C.
3.4.3 Input Connection Procedure
1. Remove left side panel of the ESP-600C
2. Thread cables through the access opening in
the rear panel.
3. Secure cables with a strain relief or conduit
coupling (not supplied) at the access opening.
4. Connect the ground lead to the stud on the
chassis base.
5. Connect the power lead ring terminals to the
primary terminals with supplied bolts, washers
and nuts.
6. Connect the input conductors to the line (wall)
disconnect.
Chassis Ground
Power Input Cable
Access opening
(rear panel)
Primary
Terminals