CAUTION: TO REDUCE THE RISK OF ELECTRIC SHOCK, DO NOT REMOVE COVER (OR BACK). NO USERSERVICEABLE PARTS INSIDE. REFER SERVICING TO QUALIFIED SERVICE PERSONNEL. The lightning flash with arrowhead symbol, within an equilateral triangle, is intended to alert the user to the presence of uninsulated “dangerous voltage” within the product’s enclosure that may be of sufficient magnitude to constitute a risk of electric shock to persons.
Contents Thank you for choosing TEAC. Read this manual carefully to get the best performance from this unit. IMPORTANT SAFETY INSTRUCTIONS . . . . . . . . . . . . . . . . . . . . . 2 Before Use . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Features Up to 192 kHz Word Sync clock production With the advent of digital equipment using higher sampling frequencies than ever, 176.4 kHz and 192 kHz word clocks (sync signals) are made available in addition to conventional 44.1 kHz, 48 kHz, 88.2 kHz and 96 kHz clocks. As an additional plus, the output circuitry consists of 3 separate channels with a total of 6 output terminals, thus offering the capability of handling a variety of audio equipment controlled by different word clocks.
Names of Each Control A B C A STANDBY/ON button When the Main Power switch on the rear panel is ON, use this button to turn the unit on or to standby. When the unit is on, the indicator lights. B MASTER button Press this button to select the signal source you will use for the reference frequency. When the clock signal is stabilized, the indicator for the MASTER button stops blinking and lights steadily.
A WORD CLOCK OUT terminals These terminals output precise word synchronization signals. Connect these OUT terminals to the WORD SYNC IN terminals of the other digital equipment, using a commercially available BNC coaxial cable. < For other connections, read the instructions of each component you intend to use with this unit. < Each of the A, B, and C channels is switch-selectable between 1xFs, 2xFs, and 4xFs. So you can, for example, connect an 88.2 kHz and a 176.
Set Up for Esoteric Units 4 Select 44.1kHz using the FREQUENCY MODE button. 2 3 4 5 5 Select the frequency of the word clock for each line by pressing the A, B or C button. This is the recommended set up for synchronization with TEAC-ESOTERIC CD units: P-70, X-01, UX-1, P-01, D-01 1 Connect WORD CLOCK OUT terminals to WORD SYNC IN terminals of each unit using commercially available BNC coaxial cables.
Set Up for DVD Players, Universal Players, etc. 5 If your units are connected to the WORD SYNC OUT terminals, select the frequency of the word clock for each line by pressing the A, B or C button. 2 3 6 4 5 This is the recommended set up for synchronizing DVD players, D/A converters and other similar digital devices. 1 Connect WORD CLOCK OUT terminals to word synchronization input terminals of your units, using commercially available BNC coaxial cables.
Dimmer Troubleshooting In case you experience any problem with this unit, please take the time to look through this chart and see if you can solve the problem yourself before you call your dealer or a TEAC service center. No power e Check the connection to the AC power supply. Check and make sure the AC source is not a switched outlet and that, if it is, the switch is turned on. Make sure there is power to the AC outlet by plugging in another item such as a lamp or fan.
Specifications Clock outputs 44.1 kHz lines . . . . . . . . . . . . . 44.1 kHz, 88.2 kHz, 176.4 kHz 48 kHz lines . . . . . . . . . . . . . . . . . . . 48 kHz, 96 kHz, 192 kHz PAL FILM lines . . . . . . . . . . 46.08 kHz, 92.1 6kHz, 184.32 kHz UNIVERSAL CLOCK lines . . . . . . . . . . . . . . . . 100 kHz, 96 kHz General Power supply . . . . . . . . . . . . . . . . . . . . . . . . AC 120 V, 60 Hz Power consumption . . . . . . 75 W (maximum), 31 W (nominal) Weight . . . . . . . . . . . . . . . . . . . . . . .
Z TEAC CORPORATION 3-7-3, Nakacho, Musashino-shi, Tokyo 180-8550, Japan Phone: (0422) 52-5081 TEAC AMERICA, INC. 7733 Telegraph Road, Montebello, California 90640 Phone: (323) 726-0303 TEAC CANADA LTD. 5939 Wallace Street, Mississauga, Ontario L4Z 1Z8, Canada Phone: (905) 890-8008 TEAC MEXICO, S.A. De C.