User`s guide

IVX X-Class Administrator’s Manual Administrator programming: An introduction
A.5
System fixed numbering plan
Numbers Function
0 Operator
1–84 CO lines
100–267 User extensions
280–299 Department numbers
300–489 Guest/info mailboxes
490–499 Q & A mailboxes
500 Broadcast mailbox
501–516 Group mailboxes
520–529 Cascade paging mailboxes
530–550 Recordable system prompts
551–589 Feature codes
590–598 MOH recordings
599 Overhead paging port
600–699 System speed dial
700–799 Esi-Link locations
988 Modem
Remote setting of day, night, holiday and auto modes
Normally, the system’s day/night mode operation will be manually controlled at an ESI Feature Phone
and/or set to follow the day/night mode tables (programmed by the Installer) automatically. In addition,
the Administrator can remotely change the mode and/or re-record the holiday greeting to handle unex-
pected closings such as for inclement weather.
Remotely logging into the system with the Administrator password lets the caller re-record the ID 1
greetings (day, night, day2 and night2) and the holiday greeting, as well as change the mode to
day/night/holiday/day2/night2 (or auto).
1.
At the main greeting, enter ½ ½
4 5 6 #
— or ½ ½ [the new password]
#
to enter remote
programming mode.
2.
You’ll hear prompts that will allow you to change the answer mode (day, night, day2, night2, holiday
or auto) and/or to re-record the holiday greeting and the main greeting (ID 1). Follow the prompts to
perform the desired operation.
3.
Exit by pressing ½ and hanging up.