Installation manual
Function 3: Extension programming IVX C-Class with voice mail: Installation Manual
F.2
7. Extension page zone assignment — List the page zones (1,2,3) that are to be included.
Default: All-page.
The overhead paging port (extension 199) can be paged along with other extensions in a
zone by including the desired page zone for extension 199.
All digital phone extensions are included in (and cannot be removed from) the all-page zone.
Analog extensions cannot be included in page zones.
8. Operator translation — Extension 0 (Operator) programming requires:
• Programming call forwarding for day and night mode
• Entering the extension number to which calls are to be directed when someone dials 0.
Default: 100.
Notes: If you want more than one extension to ring when someone dials 0, you must build a
department in Function 33 (see page F.5) and enter the department in column 8 on page F.1.
If operator translation is directed to a department or branch ID, and a call to the operator is not
answered, operator call forwarding takes precedence.
Analog ports
The last 2 station ports can be programmed only as follows:
1.
Ext.
2.
Type
3.
Name
4.
CO
0 Operator
100 DIGITAL Jane 9
101 DIGITAL Roger 9
102 DIGITAL Sally 9,8
112 PHONE/FAX/MODEM/RINGER/DOOR PHONE/FAX/MODEM/RINGER/DOOR 9
113 PHONE/FAX/MODEM/RINGER/DOOR PHONE/FAX/MODEM/RINGER/DOOR 9
Here are the steps for programming analog ports:
1. Phone number — Analog port extension numbers must be x112 or x113.
2. Type — If ANALOG PORT is selected, then the ports can further be defined as follows; the
words in parentheses (EXAMPLE) indicate what the display will show in each case:
• Phone (EXT) — Designed to provide for standard 2500 type phones. See the IVX C-Class
User’s Guide for complete description of the capabilities.
• Common ringer (RINGER) — Connected via a tip and ring pair; will apply ring voltage
whenever a line rings in night mode or when a call is directed to it (transfer, call forwarding,
CO ring, etc.).
• Fax (FAX) — If the Auto Attendant detects a fax tone, it will automatically forward the tone to
the analog port programmed as FAX.
• Modem (MODEM) — Incoming calls for a modem can be manually transferred to the
modem extension; also, the modem can automatically generate outbound calls. Maximum
connect speed through the PBX is 9600 bps.
• Door phone (DOOR) — A telephone connected to this port will automatically dial the
programmed ring down extension number whenever the set is taken off-hook.