Installation manual

Hardware overview/installation IVX C-Class Installation Manual
B.6
Opening the cabinet
The lid on all cabinets is held in place by two tabs that rest in slots in the bottom
of the case, and a release tab that snaps into an opening in the top-center of the
cabinet and is secured by a retaining screw.
To remove the lid:
1. Remove the retaining screw and depress the release tab at the top of
the cabinet.
2. Rock the lid back from the top.
3. Lift and pull the lid free from the slots in the bottom of the cabinet.
Mounting the cabinet
Use three #8 hex-head screws. Note the position of the three mounting holes in IVX.
1. Screw in the top screw to the backboard (at least
one-half-inch thick plywood) leaving about one-eighth-inch
clearance between the screw head and the plywood.
2. Hang the unit using the keyhole at the top of the case.
3. Level the unit and install the bottom two screws.
Attach the power transformer to the wall, allowing sufficient length
in both cords to reach the power connector on the upper right side
of the cabinet and to reach a UPS or a dedicated 110 VAC outlet.