Installation manual

ESI-50L Programming Manual Function 5: Voice mail programming
H.4
Function 55: Message notification
On a mailbox-by-mailbox basis for user or guest mailboxes, the system can be programmed to call an off-premises
number or another extension to deliver messages or dial to an external commercial paging network to activate a
user's pager. ESI-50L will call or page when the first new message has been left in a mailbox and will repeat (at
the interval of minutes programmed in this function) until the new message(s) have been deleted, saved or moved.
The user can program either a phone or pager number. The Installer and Administrator can set, on an individual-
station basis:
The number to be called
A delay period
The number of attempts (maximum of 99)
The interval between attempts
A “quiet period" to suspend phone delivery — e.g., late at night (the quiet period is an on-and-off time that
applies to all days of the week)
Note: Only pager or phone notification can be programmed, not both.
Function 551: Station delivery options
Programming of the station options, as shown below, can be performed by the Installer or Administrator.
In addition, the user can change his/her phone number and pager number (but not phone or pager delay
time). The phone number’s maximum length is 24 digits.
1.
Number
2.
Delay
3.
Attempts
4.
Interval
5.
Quiet on
6.
Quiet off
1. Phone 2145556789 30 6 60 10:30PM 7:15AM
2. Pager 2145551234 0 10 30
To program, enter the station/extension number and choose 1 for phone number or 2 for pager number.
Then, enter:
1. Phone/pager number — The number to be dialed (without the CO line group [9, 8, or 71–76]).
2. Delay How many minutes the system is to wait before dialing the phone or pager number.
This allows the user to pick up a message if he is in the office.
Range: 0–500. Default: 0.
3. Attempts — How many times the system will call/page.
Range: 099. (0 turns off delivery.) Default: 3.
4. Interval — How many minutes should elapse between attempts.
Range: 10–1440. Default: 30.
5. Quiet period on — When the quiet period should begin.
Default: (None.)
6. Quiet period offWhen the quiet period should end.
Default: (None.)
Notes:
For the Quiet period on or Quiet period off parameters, a value in either of 0:00 is invalid and will
cause notification not to work.
To insert a special code, press the right scroll key () to select the desired special code:
# ,
, F or P (see below). Press # to confirm the inserted character and continue.
Press # # to complete the entry. Use the down arrow key (
) to backspace.
Once the number is saved you can use the scroll keys to move back and forth to view the number.
To edit the number, you must delete it and enter the correct number.
Code What it produces
# # DTMF tone
DTMF tone
F Flash hook
P Two-second pause