User guide

88
SMTP server requires authentication If the SMTP server requires authentication, these fields should be filled in
with a valid username and password granting access to the SMTP server.
Sender address This field specifies the sender address which will be displayed in the header of notification
emails.
Recipient address This field specifies the recipient address which will be displayed in the header of notification
emails.
Send event notifications to LAN computers by means of Messenger service Select this check box to send messages
to LAN computers via the Windows® messaging service.
Send notifications to the following computers (delimited by a comma) Enter the names of computers that will
receive notifications via the Windows® messaging service.
Interval between sending messages (sec.) To change the length of the interval between notifications sent via LAN,
enter the desired time interval in seconds.
Minimum verbosity for notifications Specifies the minimum verbosity level of notifications to be sent.
Edit format... Communications between the program and a remote user or system administrator are done via
emails or LAN messages (using the Windows® messaging service). The default format of the alert messages and
notifications will be optimal for most situations. In some circumstances, you may need to change the message
format click Edit format....
4.6.11.1 Message format
Here you can set up the format of event messages that are displayed on remote computers.
Threat alert and notification messages have a predefined default format. We advise against changing this format.
However, in some circumstances (for example, if you have an automated email processing system), you may need
to change the message format.
Keywords (strings separated by % signs) are replaced in the message by the actual information as specified. The
following keywords are available:
%TimeStamp% Date and time of the event
%Scanner% Module concerned
%ComputerName% Name of the computer where the alert occurred
%ProgramName% Program that generated the alert
%InfectedObject% Name of infected file, message, etc
%VirusName% Identification of the infection
%ErrorDescription% Description of a non-virus event
The keywords %InfectedObject% and %VirusName% are only used in threat warning messages, and %
ErrorDescription% is only used in event messages.
Use local alphabetic characters Converts an email message to the ANSI character encoding based upon Windows
Regional settings (e.g. windows-1250). If you leave this deselected, a message will be converted and encoded in
ACSII 7-bit (for example "á" will be changed to "a" and an unknown symbol to "?").
Use local character encoding The email message source will be encoded to Quoted-printable (QP) format which
uses ASCII characters and can correctly transmit special national characters by email in 8-bit format (áéíóú).