Instructions / Assembly

1 - LED Sensing Light Unit 4 – Hardware Package with Screws and Anchors to mount the light body 1 -
Thank you for choosing the EE118WMC LED SMART Light. With its effortless setup and lightweight design, the EE118WMC
LED Smart Light conforms to all your lighting needs. It was designed and made to provide many years of trouble free service
using environmentally friendly LED-Doppler Sensing technology. Covered under multiple US, European, China and other
international patents granted and pending worldwide. All rights reserved. Contents:
EE118WMC User Manual
Applications
Introduction and Intellectual property Rights Statement
The Package
● What’s Inside the Package ● Installation ● Functions ● User Tips
● Specifications ● Optional Accessories ● Important Safety Information ● Limited Warranty Information
Rev. EE118WMC 02082016 Page 1
AC powered LED Sensing Light, with “All in One” Operating Capability:
Standard - Can be used for new AC lighting installations or to replace existing out-dated light fixtures or lamps as a standard
ON-OFF switch controlled light and also for AC power applications that provide continuous illumination.
*Doppler Sensing – Provides outstanding motion sensing performance and unlike standard PIR motion detection it is
effective in sensing changes in ambient temperature and it is not blocked by obstacles (wall, glass e.g.)
Smart Sensing Profiles – Can be set for either of two pre-selectable dual SMART Energy Saving Modes. If the sensor
does not detect any motion in the covered area after the pre-set delay timing window then it can be auto-set to either
Dusk to Dawn – When install it with AC power ON (without switch manually control) that it can provide all night Safety/
Security lighting; it has a built-in adjustable ambient light photo sensor that automatically turns the light on to a pre-set
lighting level when it senses a change in ambient lighting level of environmental, and the motion sensor/switcher & timer will
activate it to full brightness if motion is sensed.
Standard AC Lighting for Residential: (Fig. 1)
Standard AC Lighting for Commercial, Industrial or Public Facilities: (Fig. 2)
Please Read Carefully Before Installing the Unit!
®
Turning to Open the cover
Installation
Mount & Setup (Turn power OFF before installing)
Screw the light fixture base onto the pre-installed/existing electric
standard J-Box and connect power wires (N & L /H), refer: Fig. 1,
1A & 4. For concrete/brick/stucco surface without the J-Box: It is
best to drill clearance holes using a 3/16" masonry bit then insert
plastic anchors and screw the base into position. Make sure
mounting is secured and safe by your local electric code. Then
power ON as general lighting control for normal lighting function.
Apply as Standard Light:
Just connect with AC power source (120V AC) as any standard
lighting system. The light can be manually turned and via a
standard wall mounted switch as general lighting (all set with max)
or with motion activated or dimming function (refer: ).
Mount the base with standard J-Box
or other drill holes mount option
Wall Switch
White
Black/Red
120VAC
L/H
N
Individual New or Replacement Application
Connect two power wires
Turning to close the cover
Multiple New or Replacement Application
120VAC
CB
Black/Red
White
N
L/H
N H
6-½”

Summary of content (2 pages)