Operating instructions
Dole – Drivers Reference Manual
Page 44
4.4.3 Thermo King Magnum Plus MP4000
The display has an ON and OFF key. This key is the triangle below the Thermo King round
key.
UNIT START-UP.
Connect unit to 460 Volt shore power or genset. Turn circuit breaker on at post to apply
power to unit.
Display will show Johnson Controls
Test memory passed
Start Application
Display will go blank with just status bar
Display Thermo King Logo Please Wait.
Loading…….
Screen will go blank
Press and Hold ON/OFF Key for 2 seconds.
Display shows RA,SA,SP
PM 4000 Setup
Power Module Init
Power Module Phase test-Shows heater icon
Power module Ready
Stop Plant
Unit starts and shows CHILLED COOLING and shows mode of operation.
NOTE: Random time delays during the initial unit start-up
minimize peak current draw.