NOTE: NEVER USE STARTING FLUID. PLEASE REFER TO STARTING
INSTRUCTIONS TO THE RIGHT OF CONTROL PANEL ON GENSET.
3.6 Daily Maintenance and Operational Checks
Under-mounted diesel generator sets used in the Dole fleet are well maintained and reliable
units which have an excellent record for providing dependable service to our carriers. As
with all machinery, however, good over-the-road performance relies heavily on good
operator maintenance. The following daily operational checks and service procedures are
drivers responsibilities that must be followed closely.
a) Check the operation of your unit every four hours to ensure that all systems are
operating correctly including: A/C voltage output, engine temperature, oil pressure
and D/C amperage.
b) Daily, check all fluid levels including: oil, radiator coolant, and fuel level.
c) Do not allow your unit to run out of fuel.
d) Use only premium products when servicing your unit.
e) When operating in northern areas of the country during below freezing conditions,
treat diesel fuel with a DOT approved anti-gel additive.
f) Do not shut your unit down for extended periods when transporting refrigerated
loads.
g) Do not use, or permit the use of ether or any other unauthorized starting agent when
operating Dole equipment.
h) In the event of a generator set equipment failure, take appropriate and immediate
action to make repairs to your unit following the guidelines provided in section 5 of
this manual.
3.7 Diesel Generator Set Troubleshooting
While most repairs to Dole diesel generator sets will be performed at an authorized service
center, limited troubleshooting and repairs may be carried out by the operator in the event of
a generator shut down. The following procedures may help in determining the cause and
remedying the problem of the conditions listed below.
a) Unit shut-down due to overheating:
1. Check the overflow coolant bottle to ensure coolant level is at the proper
level. Add coolant if required.
2. Check to ensure engine V-belt is adjusted properly.
3. Check to ensure radiator coil is free from foreign material.
b) Unit shut-down due to low oil pressure:
1. Check engine oil level. Use only a 15W40 premium brand engine oil.