AUTOMATIC DIGITAL WALL MOUNTED INFLATOR Operating Instructions MODEL 10964
1. Thank you for selecting this ESCO Automatic Digital Wall Mounted Inflator. Please read this manual before carrying out any installation or service procedure. 2. This manual is an integral and essential part of the product, please keep it away from damp, heat, dust, oils, do not remove, tear or amend any parts of the manual for any reason. It must be made available to the operator and to maintenance personnel, also to ensure staff training. 3.
INSTALLATION WARNING 1. Unpack the unit. To avoid the risk of personal injury, especially to the eyes, face or skin, DO NOT direct the air stream at any person, or any part of the body. 2. Hold the unit up on the wall and mark where the four (4) holes are to be drilled. 3. Secure the unit using suitable fastener. 4. Connect the air supply to the unit. 5. Connect the rubber hose as air outlet. 6. Connect the power supply. Warning: 1.
PRODUCT IDENTIFICATION 1 CONTROL PANEL 1. Mounting Point (x 4) 4 2. - Target pressure control 5 3. + Target pressure control 8 7 2 3 4. Display 5. FLAT TIRE / CONFIRM Flat tire mode air Start/Stop control; Function Select Confirm 6 6. Unit Option Unit of measure select; Over Pressure Setting set control 7. Programmable preset button 1 8. Programmable preset button 2 Fig. 1 Control panel CONNECTIONS 9. Power cable 10. Pressurised Air Inlet 10 11 11. Air hose outlet 12 13 9 12.
Programmable Buttons: 1. Press P1 or P2 buttons once. Press + or - to select pressure desired. 2. Press the CONFIRM button once and there will be a beep to confirm the programmable button has been set to the desired pressure. 3. You can set each programmable button to a different pressure. • • • • kPa - kilo-pascals bar psi - pounds per square inch kg / cm2 - kilograms per square centimeter Once the unit is set here, it will become the default unit for following usage. 1.
troubleshooting Problem Possible Cause Solution Air leak Leak in the connection Check the pneumatic connection and The inflator works, but no air inflated Obstruction in the filters or in air system Clean the filters and check the air tube Air hose improperly connected Check the hose connection, make sure that no air leaks Tire pressure is below 0.
Calibration Certificate This Digital Wall Mounted Inflator has been calibrated in its normal working position on test equipment with an accuracy that is traceable to International Standards according to: 86/217/EEC Allowable Tolerance ±0.08 up to and including 4 bar BAR ±0.16 between 4 bar and 10 bar inclusive ±0.25 greater than 10 bar ±1.2 up to and including 58 psi p.s.i. ±2.3 between 58 and 145 psi inclusive ±3.
SPECIFICATIONS Case Heavy Duty Metal Housing Hose Length 32 ft. | 10m Dimensions 190L x 150W x 70H mm Weight 13 lbs. | 5.5 kg Scale 174 psi / 12 bar (1200 kpa / 12 kgf ) Accuracy ±0.3 psi @ 25-75 psi Max. inlet air supply 174 psi | 12 bar Supply voltage 110-240V AC (50-60 Hz) Wattage 12 W Max.